Skip to content
JINYUCOMMERCIAL KITCHEN EQUIPMENT
Menu

Four models · two door arrangements

Front-opening vs sliding-door display fridge sizes

Compare 1000-1500 mm R2F outward-opening cabinets with the 1200 mm RF2 sliding-door display. Plan the serving movement alongside the cabinet dimensions.

Compare all four models →
JINYU GN-1200R2F front-opening straight glass cake display in a cafe or bakery
JINYU GN-1200R2F · 1200 × 740 × 1385 mm outward-opening display

Display fridge sizes, shelf counts and door operation

Recorded model specifications; dimensions are width × depth × height in mm. Floor areas are calculated from the exterior cabinet outline.
JINYU modelFront and side glassW × D × H (mm)CapacityExterior footprint (m2)Rated powerShelvesService access
GN-1000R2FStraight glass front and sides1000 × 740 × 1385 mm390 L0.740470 W3 glass shelves2 front glass doors, open outward
GN-1200R2FStraight glass front and sides1200 × 740 × 1385 mm480 L0.888480 W3 glass shelves2 front glass doors, open outward
GN-1500R2FStraight glass front and sides1500 × 740 × 1385 mm610 L1.110640 W3 glass shelves2 front glass doors, open outward
GN-1200RF2Straight glass front and sides1200 × 730 × 1200 mm425 L0.876455 W2 glass shelves2 sliding doors on the service side

All four records list freestanding installation, fan cooling, R290 refrigerant, 2-8°C and 220-240V/50Hz. Exterior footprints exclude installation clearances and circulation space.

Which display fridge sizes can I compare for outward-opening and sliding doors?

The R2F range has three recorded sizes: GN-1000R2F is 1000 × 740 × 1385 mm, GN-1200R2F is 1200 × 740 × 1385 mm, and GN-1500R2F is 1500 × 740 × 1385 mm. Each lists two front glass doors that open outward. GN-1200RF2 is 1200 × 730 × 1200 mm and lists two sliding doors on the service side. All dimensions follow width × depth × height.

Start with the service position, then compare cabinet width. Mark the opening side on the plan, together with the operator and the packing surface. These four cabinets are freestanding straight-glass displays. The R2F records give three glass shelves per model; the RF2 record gives two. Keep those shelf counts with the exact model codes when requesting drawings.

What changes between the two 1200 mm-wide cabinets?

GN-1200R2F and GN-1200RF2 occupy the same 1200 mm frontage. The R2F cabinet is 740 mm deep and 1385 mm high; RF2 is 730 mm deep and 1200 mm high. R2F therefore adds 10 mm of exterior depth and 185 mm of exterior height. The calculated cabinet footprints are 0.888 and 0.876 square metres respectively, before connections and installation spacing.

Their listed capacities are 480 L and 425 L, a difference of 55 L. Their rated powers are 480 W and 455 W. Those comparisons describe the recorded cabinets; they do not establish shelf area, the number of cakes that fit, or electricity consumption over a working day. Use the door arrangement and usable shelf drawings alongside these exterior figures.

How much frontage remains beside a 1000, 1200 or 1500 mm cabinet?

For an illustrative 2000 mm-long display zone, subtracting cabinet width leaves 1000 mm beside GN-1000R2F, 800 mm beside either 1200 mm model, or 500 mm beside GN-1500R2F. These are arithmetic remainders along a hypothetical straight frontage. Allocate installation spacing from the model drawing before treating the remainder as a usable work surface.

Draw the cake box, board, wrapping tools and payment device at their measured sizes. Show where a removed tray can rest while the operator closes the door. A wider display may leave less room for that sequence, even when its listed capacity is larger. Keep the working-surface dimensions separate from the cabinet outline and from the standing space in front of the opening.

How does an outward-opening door change the service layout?

All three R2F records specify two front glass doors that open outward. Draw their opening movements into the serving area, using the selected model's door drawing. Include nearby furniture, the customer route, the operator and the surface receiving the product. Overall width and depth do not provide the panel width, opening angle or clear access dimension.

Rehearse the movement for the largest loaded tray: approach, open, remove, set down and close. Check whether another person can use the adjacent packing surface during that movement. Ask for measurements or a demonstration tied to the exact model and drawing version. A photograph of a closed cabinet cannot establish the space occupied by an open door or the path available for a loaded tray.

Do sliding doors remove the need to check access space?

GN-1200RF2 lists two sliding doors on the service side. Include the operator, tray transfer and nearby work surfaces in its plan. Ask for the clear opening at each sliding position and identify any panel overlap. The 1200 mm exterior width does not state how much of a shelf can be reached through one opening.

Measure the loaded tray or cake board, including projecting decoration or a cover. Compare its width, depth and height with the opening and the usable shelf dimensions. Show the intended serving side explicitly in the inquiry and ask for the corresponding drawing. Sliding operation and outward opening require different movement checks, but both need a route for taking a product out and setting it down.

Can I choose by litres or by the R2F and RF2 model suffixes?

Use the individual specifications. The three R2F models list 390 L, 480 L and 610 L as width increases from 1000 to 1200 to 1500 mm; each record lists three glass shelves. GN-1200RF2 lists 425 L and two glass shelves. Preserve those recorded shelf counts rather than interpreting the digits in a model suffix as a shelf specification.

Litres do not describe tray placement. Prepare an assortment list with container footprints and loaded heights, then request usable dimensions for each shelf position. Place the largest board or covered portion first in a scale layout. Check door access for that item separately. This connects capacity, shelf arrangement and serving movements to the products you actually intend to display.

What do the electrical and cooling specifications tell me?

All four records list fan cooling, R290 refrigerant, a 2-8°C temperature range and 220-240V/50Hz supply. GN-1000R2F lists 470 W, GN-1200R2F 480 W, GN-1500R2F 640 W and GN-1200RF2 455 W. Keep each power rating attached to its model when preparing the equipment schedule.

Rated power alone does not give daily energy use. Describe the room conditions, opening pattern and intended chilled assortment in the inquiry. Provide the destination supply details and request the selected configuration's electrical and installation documentation. Use that documentation when arranging the connection and required spacing. The common temperature range is a cabinet specification; product handling and storage requirements still belong in your operating plan.

What should I send with a display fridge size and door-access inquiry?

Send the shortlisted model codes, a dimensioned plan and an elevation. Mark available frontage, depth, cabinet height, serving side, packing surface and adjacent fixtures. Add the largest tray, board and covered-product measurements, plus photographs showing where staff stand and how stock reaches the display. Label any illustrative dimensions separately from measurements taken at the site.

Request the door movement or sliding-position drawing, clear opening dimensions, usable shelf layout, installation spacing, equipment weight and electrical details for each candidate. Put the model code and drawing revision on the comparison sheet so replies remain traceable. Address the inquiry to JINYU, Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司), and attach the same site brief for every model being compared.

Send the selected model codes and layout →