Plan GN-900RT and GN-1200RT on an L-shaped counter: worked corner-overlap coordinates, revised frontage balances, elevation and a downloadable CSV record.

JINYU GN-900RT straight glass cabinet on a cafe counter

Worked corner record: two 1800 × 600 mm counter legs

The legs share a 600 × 600 mm corner. Coordinates below use their common outside corner as (0, 0); x runs horizontally and y runs along the return. Each cabinet body is shown in plan. Initial, revised and swapped rows are separate alternatives.

Illustrative furniture inputs; all coordinate endpoints are in millimetres. End balances exclude installation space and staff working areas.
Arrangement / legModel bodyx endpoints, mmy endpoints, mmBody-layout result
Initial AGN-900RT0-9000-530Shares the corner with initial B
Initial BGN-1200RT, rotated0-5300-1200530 × 530 mm overlap with initial A
Revised AGN-900RT600-15000-530300 mm horizontal end balance
Revised BGN-1200RT, rotated0-530600-18000 mm return end balance
Swapped AGN-1200RT600-18000-5300 mm horizontal end balance
Swapped BGN-900RT, rotated0-530600-1500300 mm return end balance

Download the corner coordinates and site measurement record (CSV) →

Recorded countertop cabinets for this comparison

Actual JINYU cabinet records. Dimensions are width × depth × height; the coordinate exercise rotates only the plan outline.
ModelDimensionsCapacityShelvesVoltage / frequency
GN-900RT900 × 530 × 730 mm140 L2220-240V/50Hz
GN-1200RT1200 × 530 × 730 mm190 L2 chrome-plated shelves220-240V/50Hz

How do I choose display fridge sizes for an L-shaped counter?

Measure both counter legs from one shared corner and draw each cabinet as a complete rectangle. The length of the return cannot simply be added to the length of the main counter: the corner belongs to both measurements. Mark which surface occupies that shared area, where the cabinet fronts face and where staff stand behind the rear doors. Keep a plan view and an elevation together so a cabinet that fits along one edge can also be checked against overhead fittings.

The worked example uses two JINYU countertop models: GN-900RT at 900 × 530 × 730 mm and GN-1200RT at 1200 × 530 × 730 mm, stated as width × depth × height. Both have two shelves and rear sliding doors. Their recorded capacities are 140 L and 190 L respectively. These cabinet records support a body-layout comparison. The furniture measurements below are illustrative buyer inputs; replace them with measured site dimensions before requesting a layout review.

Why do two cabinets drawn from the same corner overlap?

Suppose both counter legs extend 1800 mm from the outside corner and each surface is 600 mm deep. Set the corner as coordinate (0, 0). Draw GN-900RT along the horizontal leg from x = 0 to 900 and y = 0 to 530. Rotate GN-1200RT through a right angle on the return, from x = 0 to 530 and y = 0 to 1200. Each model appears shorter than its 1800 mm leg, yet the two bodies occupy the same 530 × 530 mm corner square.

The common area is 280900 square millimetres, or 0.2809 square metres. It is a physical overlap in the drawing. The downloadable record preserves these initial coordinates so the conflict remains visible when a revised arrangement is discussed. Label the horizontal and return cabinets separately, attach the model codes and show the direction of staff access. Measuring only the front edges would miss the conflict between their complete bodies.

What happens if I reserve the 600 mm corner before placing either fridge?

In the revised example, leave the first 600 mm of each leg outside the cabinet allocations. Put GN-900RT on the horizontal leg from x = 600 to 1500 and y = 0 to 530. Put the rotated GN-1200RT on the return from x = 0 to 530 and y = 600 to 1800. These body rectangles no longer intersect. The horizontal frontage balance is 1800 minus 600 minus 900 = 300 mm; the return balance is 1800 minus 600 minus 1200 = 0 mm.

Reserving the corner demonstrates one way to remove the body overlap; 600 mm is the example furniture depth, not a JINYU installation clearance. The zero return balance identifies a fully allocated body run. Request the installation drawing before treating that arrangement as usable. Record any additional space required at ends, behind the cabinets or at connections on a revised plan. Assign a separate position for packing and handover rather than silently spending the remaining 300 mm twice.

Can I swap the 900 mm and 1200 mm cabinets between the two legs?

Yes, the arithmetic can be compared with the models exchanged, while retaining the same example corner reservation. Place GN-1200RT horizontally from x = 600 to 1800 and y = 0 to 530. Put GN-900RT on the return from x = 0 to 530 and y = 600 to 1500. The horizontal body balance becomes zero and the return balance becomes 300 mm. Cabinet depth and height remain 530 and 730 mm for both models, so this exchange changes the allocation along the legs without reducing the body depth.

Compare the staff loading position in both arrangements. Mark the service face and the full tray approach, including where an operator stands while another person packs an order. Keep those movements on the site drawing for the equipment reviewer. Adding 140 L and 190 L gives 330 L of listed cabinet capacity across the pair. That total does not establish a tray count, shelf opening or shared storage zone.

Which depth and height measurements belong in the corner review?

For a 600 mm-deep supporting surface and a 530 mm cabinet body, the total depth difference is 70 mm. Keep it as a gross body balance until the base-support drawing and installation requirements locate the cabinet on the surface. Measure raised edges, cable openings and any wall projection from the same endpoints. Send the counter construction and the requested loaded-condition information for a support review; listed litre capacity supplies no cabinet weight.

The 730 mm model height begins at its supporting surface. If the illustrative counter top is 900 mm above the floor, the cabinet top reaches 1630 mm. Draw that elevation against the actual menu board, lights and nearby shelving. A different counter height changes the elevation even when the model stays the same. At a junction between two counter sections, also record whether the tops are level and continuous. Keep the corner furniture drawing separate from the cabinet body dimensions.

What should I send with an L-shaped display fridge inquiry?

Send a dimensioned plan with both leg lengths, surface depths, the shared origin and the selected cabinet coordinates. Include the initial overlap drawing and the preferred revised arrangement so the respondent can follow the decision. Attach photographs of the whole corner and each service face, the counter elevation, tray measurements and the receiving route. Identify GN-900RT and GN-1200RT on the attachments, with their recorded 220-240V/50Hz configurations.

Request the base-support and installation drawings, usable shelf arrangement and service-access information for the selected pair. Use separate response rows for furniture support, cabinet installation and the staff working area. Keep the returned drawing revision with the measurement record. Address the equipment brief to Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司), brand JINYU. When a leg length or packing position changes, revise the coordinates and frontage balances together so purchasing and the counter designer compare the same arrangement.

Reference sources

Regional references support general planning; model-specific specifications come from the published JINYU model tables.