Buyer planning guide
Display Fridge Size for a Recess: Skirting, Columns and Counter Height
Measure a display fridge recess at three positions, account for skirting and a column, and compare GN-900RT, GN-1200RT and GN-1200RF2 body dimensions.

Worked recess survey and three cabinet body checks
Illustrative site measurements, all in millimetres. The limiting rectangular envelope is 1180 mm wide and 775 mm deep. Above the example counter, 750 mm remains to the overhead underside. The floor-standing alternative removes the counter and uses the floor datum.
| Measurement | Example | Station or datum |
|---|---|---|
| Rear width | 1280 mm | Across the rear body position |
| Centre width | 1250 mm | Across the middle body position |
| Mouth width | 1180 mm | Between the column and opposing side |
| Wall to proposed front | 800 mm | Perpendicular to the rear wall |
| Skirting projection | 25 mm | Forward from the rear wall |
| Overhead underside | 1600 mm | Above floor datum |
| Counter support top | 850 mm | Above floor datum; RT arrangement only |
| Model | Body W × D × H, mm | Listed capacity | Support datum | Width balance, mm | Depth balance, mm | Height balance, mm |
|---|---|---|---|---|---|---|
| GN-900RT | 900 × 530 × 730 | 140 L | 850 mm counter top | 280 | 245 | 20 |
| GN-1200RT | 1200 × 530 × 730 | 190 L | 850 mm counter top | -20 | 245 | 20 |
| GN-1200RF2 | 1200 × 730 × 1200 | 425 L | Floor; counter removed | -20 | 45 | 400 |
The GN-900RT row leaves 280 mm in width, 245 mm in depth and 20 mm in height. Both 1200 mm-wide alternatives exceed the example's limiting width by 20 mm. Cabinet-body arithmetic does not supply ventilation, support, connection or rear-door access requirements.
Which display fridge size should I compare with a recessed position?
Compare the cabinet body with a measured space envelope that includes the recess mouth, the back wall and every fixed projection. A single wall-to-wall width can miss a column at the entrance or skirting behind the cabinet base. Record width, depth and height as separate measurements, with the location and height of each reading. Mark the intended customer front and the staff service side on the same plan. This establishes the position being evaluated before the equipment shortlist changes.
Three recorded JINYU models illustrate the comparison. GN-900RT is a 900 × 530 × 730 mm countertop display with 140 L listed capacity. GN-1200RT is 1200 × 530 × 730 mm with 190 L. GN-1200RF2 is a 1200 × 730 × 1200 mm freestanding display with 425 L. The two 1200 mm models share a width but occupy different depths and heights. Use the model-specific drawing alongside these catalogue dimensions.
Where should I measure the width when a column narrows the opening?
Measure across the mouth, across the proposed cabinet centre and across the rear position. Identify where a column begins and ends in plan, then record its height range. A projection beside the body can reduce the standing space; one in front of the body can constrain the movement into position. Keep those two checks visible even when they share the same obstruction. Photograph the tape endpoints so another person can reproduce the readings.
The worked survey below has 1280 mm at the back, 1250 mm at the centre and 1180 mm at the mouth. For an initial rectangular-envelope screen, use 1180 mm. GN-900RT leaves a 280 mm width balance, while either 1200 mm cabinet exceeds that envelope by 20 mm. These figures describe the example geometry. A wider rear wall does not resolve the narrow mouth, and a positive balance does not establish installation approval.
How do skirting boards change the available cabinet depth?
Use a common reference line for the wall and the planned cabinet front. Measure the distance between them, then identify anything projecting forward from that wall: skirting, pipe boxing, sockets or a structural base. Record each projection separately with its height above the supporting surface. This avoids deducting two measurements of the same obstruction. A cabinet drawing is needed to establish how the actual base and rear components relate to those heights.
In the example, the front line is 800 mm from the rear wall and the skirting projects 25 mm. The conservative rectangular depth envelope is therefore 775 mm. Subtracting the 530 mm RT body depth leaves 245 mm; subtracting the 730 mm RF2 body depth leaves 45 mm. Both are arithmetic balances before ventilation, connections and service space. Retain the 800 mm and 25 mm measurements in the record so the reviewer can reconstruct the calculation.
How should counter height and an overhead shelf be recorded?
Measure from the supporting surface to the underside of the lowest obstruction. For a countertop model, also record the counter height above the floor and identify the support structure. For a floor-standing model, use the floor as the supporting datum. Write the datum beside every height so a floor-to-shelf figure is not mistaken for the space above a counter. Check support requirements using the offered equipment documents and the actual counter construction.
An illustrative overhead underside is 1600 mm above the floor. With an 850 mm counter, the space above its top is 750 mm. Either 730 mm-high RT body leaves 20 mm vertically before installation allowances. In a separate floor-standing arrangement with the counter removed, the 1200 mm-high RF2 body leaves 400 mm below the same overhead underside. The worksheet treats these as alternative support arrangements. Their height balances cannot be combined into one installation.
Does a positive body balance mean the display can operate inside the recess?
A body-envelope comparison answers a geometry question using the listed exterior dimensions. Obtain the offered configuration's ventilation, connection and service requirements, then apply them to the measured plan. Show where staff reach the rear sliding doors and how they remove trays or shelves. A wall immediately behind that service side changes access even if the cabinet rectangle sits within the available width and depth. Keep the intended access arrangement in the inquiry.
For GN-900RT in this example, the calculated width, depth and vertical balances are 280, 245 and 20 mm respectively. Each remainder belongs to a different axis; adding them has no useful fit meaning. Record the actual allocation on each side and the installation drawing revision used to review it. If the recess is intended for an enclosed built-in installation, ask JINYU to assess that application against the offered cabinet rather than inferring suitability from its outside size.
What should I send for a recess-size review and model shortlist?
Send a plan and elevation with the measurement stations labelled, the three width readings, the wall-to-front depth, each projection and the supporting-surface height. Add photographs showing the recess mouth, rear wall, overhead underside and staff approach. Include the full model code for each alternative, the intended tray or pack sizes and the site electrical supply. The three models compared here record 220-240V/50Hz; the equipment response should identify the configuration being offered.
Download the worked CSV and replace its illustrative site values with your measured readings while preserving the units and station labels. Keep the model body figures separate from the site survey. In an inquiry to Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司), identify the drawing or installation question beside the affected row. When an obstruction or model changes, update the corresponding calculation and retain the previous revision so the purchasing and site teams can follow the difference.
Reference sources
- Compare display fridge sizes across the catalogue
- Review doorway access separately
- Check counter support and total height
- Send the measured recess and shortlist