Buyer planning guide
Display Fridge Size: Drawing and Measurement Discrepancy Record
Reconcile catalogue, proposal and measured display fridge dimensions with six real JINYU model outlines, endpoint photos and an 18-row discrepancy CSV.

Six model outlines and an editable dimension record
Use one row per axis when recording a difference. The CSV contains 18 rows: width, depth and height for each cabinet below. It preserves the catalogue reference while leaving the actual proposal, observation, photo and response fields empty.
Download the dimension discrepancy record (CSV) ↓
| Model | Width (mm) | Depth (mm) | Height (mm) |
|---|---|---|---|
| GN-900CT | 900 | 530 | 730 |
| GN-1200CT | 1200 | 530 | 730 |
| GN-660RT | 660 | 530 | 730 |
| GN-900RT | 900 | 530 | 730 |
| GN-1200RT | 1200 | 530 | 730 |
| GN-1200RF2 | 1200 | 730 | 1200 |
Example calculation: observed 1206 mm minus proposal 1200 mm equals +6 mm. This illustrative difference records two readings; the equipment documents and response determine how the project treats it.
Keep each edited CSV with its referenced drawings and photographs. Repeat a model's rows when comparing another proposal or revision, and retain the previous version under its original reference.
What should I do when a display fridge size differs between documents?
Identify the full model code, the document revision and the measurement being compared before changing the counter plan. Put the catalogue dimension, offered drawing dimension and observed measurement in separate columns. Preserve the unit and the endpoints used for each value. A difference between an outside cabinet width and a packed crate width describes two objects; a difference between two stated outside widths needs a response tied to the selected configuration.
Start one discrepancy record for each affected model and axis. Give the record a reference such as DIM-01 and link it to the equipment schedule. The downloadable CSV below supplies six real JINYU cabinet outlines as starting references, with separate width, depth and height rows. Its proposal and observed-value fields are blank so the project team can enter the actual evidence.
How can I check whether I am comparing the same cabinet?
Copy the complete model code from each document, including the series letters and suffix. GN-1200CT and GN-1200RT both have a published outline of 1200 × 530 × 730 mm. GN-1200RF2 is also 1200 mm wide, but its listed depth is 730 mm and its height is 1200 mm. A matching width therefore leaves the model identity unresolved. Keep a model-label photograph or proposal line beside the dimensions.
The record separates a catalogue reference from an offered configuration. If a proposal substitutes GN-1200RF2 for GN-1200RT, create a separate equipment line and request its drawing. The resulting 200 mm depth increase and 470 mm height increase belong to a model substitution. Calling them a measurement error would conceal the equipment change from the person revising the layout.
Which measurement endpoints should appear in the photographs?
Show the two physical points defining the reading and identify the axis on an accompanying sketch. For width, distinguish the cabinet body from any projection included in the offered drawing. For depth, show the front and rear endpoints and the equipment condition during measurement. For height, show the supporting plane and the top endpoint. Write down any feet, fittings or packaging included in that reading.
Take an overview identifying the cabinet and a closer view showing the reading. Retain the original images alongside annotated copies, using the same record reference in both filenames. A photograph of a tape number without its endpoints cannot explain the measured object. Ask the respondent to state which components the drawing includes, then compare against that definition before reporting a dimensional difference.
How should I calculate and describe a dimensional difference?
Use one unit throughout the calculation and subtract the reference from the compared value. In an illustrative project record, a drawing width of 1200 mm and an observed width of 1206 mm give 1206 - 1200 = +6 mm. The positive sign means the observed reading is larger. These figures illustrate the calculation; they are not an observed JINYU cabinet measurement or a manufacturing tolerance.
Record the result beside both source values. Keep catalogue-to-proposal and proposal-to-observation comparisons on separate lines if both are needed. Preserve the original precision, measurement method and document revision. A numerical difference alone does not establish an acceptance decision. Request the applicable dimensional definition and any stated tolerance from the equipment documentation, then record the response with the affected line.
How do I prevent a cabinet measurement from being confused with shipping size?
Give the cabinet body, packed shipment and installation envelope distinct names in the equipment schedule. The published GN-900CT body is 900 × 530 × 730 mm. Those dimensions identify its exterior outline. The shipment-specific package record supplies the packed dimensions; the offered installation drawing supplies the additional access and connection areas relevant to the site. Enter each set under its own measurement type.
If a carrier sends a larger packed width, put that value in the cargo schedule with its package identifier. Retain the cabinet width in the layout record. If the counter designer instead receives a revised cabinet drawing, compare that drawing against the equipment line and assess the affected joinery dimensions. Keeping the objects named makes the follow-up request specific to the document that actually changed.
What should happen to the counter drawing after a discrepancy is answered?
Link the response to the affected equipment position and drawing revision. Identify whether the explanation changes the cabinet outline, adds a projection, corrects a document entry or replaces the proposed model. Ask the counter designer to record which dimensions in the joinery plan use the revised information. Keep the earlier drawing and the response together so comments on the previous arrangement remain understandable.
For example, position C1 might reference a GN-1200RT while an earlier plan still shows GN-900RT. Their listed widths differ by 300 mm, with the same 530 mm depth and 730 mm height. Update the model reference and the width annotation together. Record the revised plan reference in the discrepancy sheet, then return that version to everyone reviewing the cabinet position.
What should I send JINYU for a dimension discrepancy review?
Send the completed rows for the selected model, the proposal and drawing revisions, the endpoint sketch and the original measurement photographs. Identify the equipment position and the exact question against each axis. Include the current counter or room drawing where the difference affects another dimension. Leave fields without a source empty and state which document or measurement you are requesting in the response field.
Address the inquiry to JINYU, Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司). Ask the reply to identify the offered configuration and provide the corresponding dimensioned drawing. Save the response reference and the resulting layout revision in the same record. This creates a traceable handover from the purchasing question to the drawing used for the actual cabinet position.