Convert three real JINYU display fridge sizes to 1:10, 1:20, 1:25 and 1:50 paper dimensions, with plan, elevation and print-scale checks.

JINYU GN-1200RT straight glass countertop cake display

Scale worksheet: real cabinet dimensions and paper rectangles

All measurements below are in millimetres. Plan = width × depth; front elevation = width × height. Each paper dimension equals the corresponding cabinet dimension divided by the scale denominator.

Exterior cabinet outlines; installation clearances and packed dimensions require their own drawings
JINYU modelReal W × D × H (mm)ScalePaper plan W × D (mm)Paper front W × H (mm)1000 mm reference on paper
GN-900CT900 × 530 × 7301:1090 × 5390 × 73100 mm
GN-900CT900 × 530 × 7301:2045 × 26.545 × 36.550 mm
GN-900CT900 × 530 × 7301:2536 × 21.236 × 29.240 mm
GN-900CT900 × 530 × 7301:5018 × 10.618 × 14.620 mm
GN-1200RT1200 × 530 × 7301:10120 × 53120 × 73100 mm
GN-1200RT1200 × 530 × 7301:2060 × 26.560 × 36.550 mm
GN-1200RT1200 × 530 × 7301:2548 × 21.248 × 29.240 mm
GN-1200RT1200 × 530 × 7301:5024 × 10.624 × 14.620 mm
GN-1200RF21200 × 730 × 12001:10120 × 73120 × 120100 mm
GN-1200RF21200 × 730 × 12001:2060 × 36.560 × 6050 mm
GN-1200RF21200 × 730 × 12001:2548 × 29.248 × 4840 mm
GN-1200RF21200 × 730 × 12001:5024 × 14.624 × 2420 mm

Worked elevation example: a buyer-measured 900 mm counter plus the 730 mm GN-1200RT cabinet gives 1630 mm overall. At 1:20, draw the supporting surface at 45 mm and the cabinet top at 81.5 mm above the floor reference. The counter height is illustrative.

Drawing record: model code; dimension source; plan scale; elevation scale; site measurement date; document revision; measured print reference; installation drawing reference.

How do I draw a display fridge size to scale on a cafe plan?

Divide each real measurement by the scale denominator and keep the result in the same unit. At 1:20, a 1200 mm cabinet width becomes 60 mm on paper. Draw the width and depth in plan view; draw the width and height in front elevation. Label the model code, dimension order and scale beside each view so the counter designer can distinguish the cabinet outline from the surrounding construction.

Start from the selected model's published dimensions and retain the dimensioned equipment drawing with the plan. The table below converts three real JINYU cabinet outlines at four scales. Its paper measurements describe exterior rectangles. Add ventilation, connections and service access from the offered configuration's installation drawing as separately labelled areas. Keep the original dimensions written beside the scaled outline so another reader can check the calculation.

Which model dimensions belong in plan view and front elevation?

For JINYU GN-900CT, the published width, depth and height are 900 × 530 × 730 mm. Its plan rectangle is therefore 900 × 530 mm at full size, while its front elevation is 900 × 730 mm. GN-1200RT measures 1200 × 530 × 730 mm. GN-1200RF2 measures 1200 × 730 × 1200 mm. All three references use width × depth × height in that order.

At 1:20, GN-1200RT occupies a 60 × 26.5 mm rectangle in plan and a 60 × 36.5 mm rectangle in front elevation. GN-1200RF2 has the same paper width but a 36.5 mm plan depth and 60 mm elevation height. Keep both views when comparing these two 1200 mm models. A width-only sketch would conceal their 200 mm difference in depth and 470 mm difference in height.

Should I choose 1:10, 1:20, 1:25 or 1:50 for the cabinet sketch?

Choose a scale that leaves the relevant cabinet, adjacent counter and measurement labels readable on the sheet being used. At 1:10, GN-1200RT is 120 mm wide on paper; at 1:50 it is 24 mm wide. The larger drawing gives more room for nearby details, while the smaller rectangle takes less sheet space when showing the whole room. State the chosen scale on each view if the room plan and cabinet detail use different scales.

Keep decimals during the conversion. The 530 mm depth becomes 26.5 mm at 1:20 and 21.2 mm at 1:25. Rounding either figure to a whole centimetre changes the rectangle substantially. The worksheet preserves those exact values and uses millimetres throughout. If a drawing program uses metres, enter 0.53 m for that real depth and check the program's unit setting before placing the cabinet.

How can I check that a printed or resized drawing still has the stated scale?

Add a dimensioned reference line to the drawing and measure it on the actual print. A 1000 mm reference should print as 100 mm at 1:10, 50 mm at 1:20, 40 mm at 1:25 or 20 mm at 1:50. Record which sheet and print were checked. A PDF viewed at a particular screen zoom has a different physical presentation from a measured paper copy.

Printing with a fit-to-page setting or resizing a screenshot can change the paper size of every rectangle. Compare the measured reference line with the expected value before taking paper measurements from that copy. Keep the written real dimensions visible even when sharing an image of the drawing. When communicating a discrepancy, report the model, actual dimension, stated scale and measured paper length together, rather than sending an unlabelled cropped screenshot.

How should a countertop display appear in an elevation drawing?

Draw the counter height from the measured site record, then place the cabinet elevation on its supporting surface. GN-900CT and GN-1200RT each have a listed cabinet height of 730 mm. In an illustrative site with a 900 mm supporting surface, the arithmetic top height is 900 + 730 = 1630 mm above the floor. At 1:20, that is 81.5 mm on paper. The 900 mm counter is an example site measurement, not a JINYU product specification.

Show the counter surface, cabinet top and nearby fixtures as separately labelled levels. Keep the counter construction and equipment base drawing in the support-review documents. The elevation helps communicate position and sightlines; the support review needs the cabinet weight and contact arrangement. For a floor-standing GN-1200RF2, draw its listed 1200 mm cabinet height from the proposed floor position instead of adding the example counter beneath it.

Can a scaled cabinet rectangle prove that trays, doors and delivery routes fit?

Use the exterior rectangle to discuss the cabinet's position. Request the specific shelf dimensions and loading opening when checking products inside it. Neither the paper rectangle nor the published outside width establishes a usable shelf measurement. Give a cake board, tray or closed pack its own measured outline and compare it with the offered configuration's internal drawing.

For door movement, ventilation and maintenance, add the areas shown in the model-specific installation documentation. For delivery, obtain the actual packed dimensions and handling information, then review the measured route with the receiving team. Keep these overlays named on the drawing. This makes it possible to see whether a question concerns the cabinet body, an operating movement or the packed shipment, and to send the correct document request with the model code.

What should I send JINYU with my scale drawing?

Send the model code, source cabinet dimensions, chosen scale, site measurements and a labelled plan and elevation. Include the dimensioned reference line and identify which print or PDF revision was checked. Mark the proposed cabinet position, adjacent fixtures and the specific area requiring review. Attach site photographs using the same position labels as the plan so the recipient can connect the drawing to the premises.

Address the inquiry to JINYU, Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司). Request the offered configuration's dimensioned equipment and installation drawings for comparison. If the shortlist changes from GN-1200RT to GN-1200RF2, replace both the plan rectangle and elevation using the corresponding measurements. Retain the earlier model as a separately identified alternative so comments about its outline remain attached to the correct cabinet.