How do I check a display fridge size beside a structural column?
Draw the proposed cabinet body and the measured column on one plan, using the same origin and unit. Give the cabinet its full model code and label the column separately. The table compares three real JINYU cabinet footprints with three illustrative column positions each. It calculates whether their rectangles share any area, giving nine reproducible geometric checks.
The column positions are examples, not measurements from a customer site. Replace them with your survey before using the worksheet for a project. The cabinet dimensions come from the model records; column dimensions come from the building survey. Keep those two sources distinct so a furniture revision does not accidentally change the equipment specification.
Which real cabinet dimensions are used in the comparison?
GN-900RT measures 900 × 530 × 730 mm, and GN-1200RT measures 1200 × 530 × 730 mm. These countertop models have different widths but the same recorded depth and height. GN-1200RF2 measures 1200 × 730 × 1200 mm. It shares the larger RT model's width while extending 200 mm farther along the depth axis and 470 mm higher.
The plan check uses width and depth, with cabinet height recorded separately. That makes the difference between the two 1200 mm cabinets visible when a column crosses the rear of the footprint. Use an elevation to review objects that occur only above or below the cabinet. A plan rectangle alone does not establish whether two objects overlap vertically.
How are the column positions measured from the cabinet origin?
Set the cabinet's front-left body corner at x = 0, y = 0. In this worksheet, x increases to the right along the cabinet width and y increases rearward along its depth. Enter the column's nearest left edge as x and its nearest front edge as y, then record the column's width and depth. Keep all four values in millimetres.
For example C1, x = 950 and y = 100 place a 200 × 200 mm column between x = 950-1150 and y = 100-300. GN-900RT ends at x = 900, leaving a 50 mm horizontal body gap. GN-1200RT extends to x = 1200, so the same column occupies part of its footprint.
How is the area shared by a cabinet and a column calculated?
Compare the two intervals on each plan axis. Along x, subtract the larger left edge from the smaller right edge, and use zero when the result is negative. Repeat along y. Multiplying those two overlap lengths gives the shared rectangle area. The table displays both lengths in mm and their product in square metres, rounded to four decimals.
For C2, the column covers x = 500-700 and y = 500-700. Either RT model overlaps it by 200 mm in x and 30 mm in y, producing 6000 square millimetres, or 0.0060 square metres. The deeper GN-1200RF2 overlaps the full 200 × 200 mm column, giving 0.0400 square metres.
Does zero shared area mean the cabinet can be installed there?
Zero shared area describes the two body rectangles only. C1 clears the GN-900RT body by 50 mm along x, but that figure supplies no ventilation, connection or service requirement. Ask for the offered cabinet's installation drawing and mark the additional space it specifies around the equipment. Compare that complete arrangement with the measured column and adjoining furniture.
A column may also interrupt rear loading access without entering the body outline. Show the staff approach, loading side and intended packing destination on a separate plan layer. Keep the geometric result and the installation review as separate entries in the project record. If the offered configuration changes, repeat both checks against its current drawing.
What does a positive overlap tell the counter designer?
A positive result identifies a shared region in the plan. If a structural column and the cabinet occupy the same vertical range, the proposed bodies cannot occupy that region together. Record the model, the affected column and the two overlap lengths, then revise the cabinet position or equipment selection in the drawing. The calculation supplies no permission to modify a column or cabinet.
C3 places a 200 × 200 mm column fully inside every example footprint, so all three rows show 0.0400 square metres of shared area. A wider cabinet does not resolve that placement. Measure the proposed replacement position from the same reference lines, then enter new coordinates and retain the earlier revision for comparison.
How should projections and height differences be recorded?
Measure the actual column surface, including cladding or a projecting base where it affects the cabinet position. If its shape changes with height, draw separate outlines at the relevant elevations. Add the supporting counter height for a countertop cabinet and compare the column profile over the cabinet's proposed vertical extent. Retain photographs showing the measurement endpoints and the full obstruction.
The worksheet uses a rectangular column section and a rectangular cabinet body. A chamfer, curved cladding or a projection needs a drawing that captures its actual shape. Label which surface each coordinate refers to. Keep pipes, skirting, sockets and overhead objects as separate surveyed features so their locations remain understandable when the cabinet moves.
What should I send with a display fridge obstruction inquiry?
Attach the full model code, a dimensioned floor plan and the column survey with a common origin. Include front and side elevations, counter height where relevant, and photographs labelled with the column identifier. The CSV provides nine worked reference rows: three models crossed with C1, C2 and C3. Copy the structure into your project record and replace the example coordinates with your measured values.
Ask Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司) for the offered model's installation, access and connection documents. Keep the response linked to the model and drawing revision. After any change in cabinet position, column finish or equipment selection, recalculate the body intersection and review the additional installation space on the revised plan.
