Compare 530 and 730 mm-deep JINYU display fridges in single-wall and facing-row layouts, with six worked room-depth calculations and supporting-counter measurements.

Compare recorded specifications →
JINYU GN-1000CF2 curved glass cake display with two glass shelves in a cafe
JINYU GN-1000CF2 curved-glass cake display. Compare its 730 mm body depth with the RT cabinets below.

Four cabinet sizes for the layout shortlist

Outside dimensions in mm; capacities and shelf arrangements from individual model records.
ModelW × D × H (mm)CapacityShelvesAccess
GN-900RT900 × 530 × 730140 L22 sliding doors at rear
GN-1200RT1200 × 530 × 730190 L2 chrome-plated shelvesSliding doors at rear
GN-1000CF21000 × 730 × 1200265 L2 glass shelves2 sliding doors on the service side
GN-1500CF21500 × 730 × 1200345 L2 glass shelves2 sliding doors on the service side

Worked depth balances in an illustrative 3000 mm room

Gross balance = room depth minus the cabinet bodies. Allocate supporting furniture, installation spacing and access on the actual plan.

All dimensions in mm. Values describe arithmetic examples, not prescribed aisle dimensions.
LayoutFirst bodyOpposite bodyGross balance
Single row53002470
Single row73002270
Facing rows5305301940
Facing rows5307301740
Facing rows7305301740
Facing rows7307301540

How do display fridge sizes affect a room with two facing rows?

Start with the room depth between the actual fixed boundaries, then subtract the bodies of the cabinets placed on both sides. What remains is a gross balance for the space between them and any installation spacing behind them. This calculation helps compare layouts before requesting the installation drawings. It does not establish a finished aisle width.

The four JINYU cabinets below provide two depth families: GN-900RT and GN-1200RT are 530 mm deep countertop displays; GN-1000CF2 and GN-1500CF2 are 730 mm deep freestanding displays. Pairing the two families gives combined body depths of 1060, 1260 or 1460 mm. Those totals change the space left in a room even when the equipment fronts appear aligned on a sketch.

What is left across an illustrative 3000 mm room?

Two 530 mm-deep cabinet bodies use 1060 mm, leaving 1940 mm from an illustrative 3000 mm room depth. One 530 mm body opposite one 730 mm body uses 1260 mm and leaves 1740 mm. Two 730 mm bodies use 1460 mm and leave 1540 mm. The calculation table keeps the room dimension, both body depths and the gross balance visible in separate columns.

Use the measured room depth in the same equation for your own site. Deduct installation spacing and other projections separately on the plan, using the selected configuration drawings. If furniture extends beyond the cabinet body, use the outermost furniture edge in the relevant part of the layout. Do not label the gross balance as an approved customer or staff aisle.

How does a single wall row compare with two facing rows?

With cabinets along only one side of the same illustrative 3000 mm room, a 530 mm body leaves 2470 mm before other allocations, while a 730 mm body leaves 2270 mm. These single-row figures differ from the facing-row balances because only one cabinet depth is deducted. The space on the opposite side still needs to accommodate the actual room use and any furniture placed there.

Draw both arrangements with the same room boundaries and cabinet outlines. Mark the entrance, till and packing surface on each version. Compare the customer approach and the staff loading position on the resulting plan. Moving a cabinet from one wall to the opposite side changes its access relationship to those features, even when the sum of cabinet depths stays unchanged.

Why must a countertop display include its supporting furniture?

GN-900RT measures 900 × 530 × 730 mm with 140 L listed capacity; GN-1200RT measures 1200 × 530 × 730 mm with 190 L. GN-900RT lists two shelves, while GN-1200RT lists two chrome-plated shelves. Both use rear sliding doors. Their 530 mm depth describes the cabinet body. A supporting counter may extend farther into the room, and its legs, front panels or rear worktop can determine the occupied footprint at a particular height.

Measure the proposed supporting furniture independently. Draw its outer outline beneath the cabinet and show where the rear doors will be accessed. If a counter is deeper than the cabinet, use that counter depth for the room-space calculation wherever it forms the limiting edge. Cabinet height also starts at the supporting surface, so record the finished counter height on the elevation.

How do wider cabinets change a facing-row plan?

GN-1000CF2 measures 1000 × 730 × 1200 mm with 265 L listed capacity; GN-1500CF2 measures 1500 × 730 × 1200 mm with 345 L. Both have two glass shelves and service-side sliding doors. Substituting the 1500 mm model adds 500 mm along the row while retaining the same 730 mm body depth. The cross-room depth calculation therefore stays the same for that substitution.

The plan still changes at the ends of the row. Draw the additional frontage beside the actual entrance and adjacent equipment. Check where people move around the cabinet end and where a packing surface can stand. A depth balance cannot describe those end conditions. Keep cabinet width and row length in a separate part of the worksheet so they remain visible when models are substituted.

Where should staff loading appear on the drawing?

Add an arrow identifying the service side of each cabinet, then show the intended staff standing position and the approach to it. The four models in this comparison use rear or service-side sliding doors. A plan that shows only their customer-facing fronts can hide the space needed to load them. In a facing-row arrangement, establish which side of each row serves customers and which side staff can reach.

Ask for the installation and access drawings against the proposed model configuration. Show adjacent furniture and its opening movements on the same plan. Keep customer circulation, replenishment and packing positions distinguishable in the drawing legend. The gross depth balance provides a starting measurement to allocate among these activities; it does not supply the allocation or the installation requirements.

Can I compare an island with a wall installation using these numbers?

Use the cabinet bodies as the first outlines for either arrangement, then add the actual supporting furniture, access sides and installation dimensions. For an island proposal, mark every exposed edge and the route around each end. For a wall proposal, locate the wall and any rear obstructions with measurements. Ask for the selected configuration requirements before fixing the relationship between the cabinet and those boundaries.

The tables do not establish that every cabinet supports every proposed island or wall arrangement. They compare recorded outside dimensions. Send both layout versions with position references and ask for a model-specific response on each. If the proposed furniture or orientation changes, revise the occupied outline and repeat the room-space calculation rather than carrying forward the earlier gross balance.

What should I send for a review of the two layout options?

Send a measured plan with the room boundaries, proposed model codes and cabinet positions to Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司). Include the counter outlines for the RT options, loading-side arrows, customer approach and the location of nearby equipment. Add a separate elevation showing counter level, cabinet top and overhead fittings.

Ask for the proposed installation drawings and usable shelf dimensions for the selected models. Include actual cake-board or finished-pack measurements when comparing the display arrangement. Identify which plan revision contains each alternative and keep the returned response beside that version. Delivery access belongs on a separate route sheet with packed dimensions requested for the shipment. This keeps room planning, interior product fit and transport access connected to the same model shortlist without mixing their measurements.