Skip to content
JINYUCOMMERCIAL KITCHEN EQUIPMENT
Menu

Site measurements · cabinet body · drawing revision

Display Fridge Size: Check a Range of Opening Measurements

Compare uneven opening measurements with three JINYU RT display fridge sizes. Read minimum and maximum differences, keep drawing revisions and download the range worksheet.

Read the range comparison →
JINYU GN-660RT countertop cake display with two raised shelves and a lower deck at a breakfast counter
JINYU GN-660RT: recorded cabinet body 660 × 530 × 730 mm, in width × depth × height order.

Three cabinet bodies against one illustrative opening survey

Example site readings: width 1195-1210 mm, depth 525-545 mm and height 725-745 mm. These are illustrative buyer measurements. Each difference equals an opening reading minus the recorded cabinet body dimension, in mm.

A negative difference identifies a reading smaller than the cabinet body. These calculations do not specify installation clearances or manufacturing tolerances.
ModelAxisCabinet mmOpening range mmSmallest difference mmLargest difference mm
GN-660RTwidth6601195-1210+535+550
GN-660RTdepth530525-545-5+15
GN-660RTheight730725-745-5+15
GN-900RTwidth9001195-1210+295+310
GN-900RTdepth530525-545-5+15
GN-900RTheight730725-745-5+15
GN-1200RTwidth12001195-1210-5+10
GN-1200RTdepth530525-545-5+15
GN-1200RTheight730725-745-5+15

Download the measurement-range CSV worksheet. It includes the nine worked rows and blank columns for your readings, site evidence and drawing revision.

How do I choose a display fridge size when my opening measurements differ?

Keep the smallest and largest reading for each dimension instead of choosing the most convenient number. Measure clear width at the front, middle and rear of the proposed position. Measure depth from the same front reference to the obstruction behind it, and height from the support surface to the lowest overhead obstruction. Give each reading a location on a sketch. Recheck a surprising result with the measurement endpoints visible in a photograph.

A width that changes across a recess can reflect its shape, a projecting trim or a different measuring position. Keep that explanation beside the readings. The worked table below uses an illustrative opening recorded as 1195-1210 mm wide, 525-545 mm deep and 725-745 mm high. Compare all three ranges with the selected cabinet body before asking for its installation drawing.

What does the range calculation show for three countertop displays?

GN-660RT measures 660 × 530 × 730 mm, GN-900RT measures 900 × 530 × 730 mm, and GN-1200RT measures 1200 × 530 × 730 mm. These are recorded cabinet dimensions in width, depth and height order. For each axis, subtract that cabinet dimension from both ends of the opening range. The result preserves the spread of the site readings rather than hiding it inside an average.

For GN-1200RT, width differences run from -5 to +10 mm. The narrowest recorded width is therefore 5 mm smaller than the listed body width. For GN-900RT, the width differences are +295 to +310 mm. All three models produce depth differences of -5 to +15 mm and height differences of -5 to +15 mm. Selecting a narrower cabinet changes the width comparison; the depth and height questions remain.

Why is a positive difference not an installation clearance?

The table compares a measured space with a catalogue body outline. A positive result describes that subtraction only. Installation questions also involve the offered configuration, service access, ventilation, cable routing, support and the movement used to put the cabinet into position. Request the applicable model drawing and instructions, then mark their requirements on the same site sketch.

Keep the body comparison and the installation review in separate columns. For example, a +295 mm width difference for GN-900RT does not assign that space to either side of the cabinet. An installer may need a specific arrangement that the opening survey has not described. Record where each requested space is needed and which document supplies it. Use the returned drawing revision when the buyer and installer review the proposed location.

Should I average the readings or call the spread a manufacturing tolerance?

Retain the original readings. In the worked example, averaging 1195 and 1210 mm gives 1202.5 mm, which conceals the narrower location when compared with a 1200 mm cabinet. The smallest reading identifies a point to investigate; the sketch explains whether the cabinet would occupy that point. Check the actual proposed position rather than reducing the survey to a single convenient width.

The spread of site readings is also different from a cabinet manufacturing tolerance. This guide supplies no tolerance for the RT models. Ask for configuration-specific dimension information where it affects the decision. If the returned drawing changes a body dimension, repeat the subtraction with that value and retain both comparison revisions. Keep the drawing's units and measurement endpoints visible so a body size, a packed size and a service-space dimension cannot be mistaken for one another.

How should I record obstructions that affect only part of the space?

Identify each obstruction by location and height above the supporting surface. A trim at the back of a recess and a bracket beneath an overhead shelf affect different parts of the cabinet envelope. Photograph each one with a scale and mark its projection on the plan or side view. Associate every reduced reading with that obstruction, rather than putting an unexplained minimum into the equipment schedule.

Record the proposed front edge of the display and the route used to position it. A deeper available area behind the cabinet does not describe the space available while it passes a narrower entrance. Use the doorway and delivery-route guides for that separate movement review. For a countertop RT cabinet, attach the counter's support review as well. The range worksheet connects these records through the model code and site position.

What belongs in a measurement-range worksheet sent with an inquiry?

Use one site-position identifier and one survey revision. Include the width, depth and height readings with their locations; identify the smallest reading on each axis; and name the model being compared. Attach the sketch, photographs and the model drawing reference when available. The downloadable CSV carries the worked example and leaves columns for a real survey, its evidence reference and the returned drawing revision.

Send each candidate as a complete model code. A GN-660RT comparison belongs on its own rows even though its depth and height match GN-900RT and GN-1200RT. Keep the person who measured the position and the measurement date in the accompanying site record. Ask the respondent to identify which drawing and configuration its answer covers, then return that answer to the installer reviewing the location.

What should change after the site is remeasured?

Replace the survey revision and recalculate every affected axis. Suppose a recheck establishes a 1215 mm minimum width at the actual cabinet position. Against the listed 1200 mm GN-1200RT body, that gives a 15 mm minimum width difference. It changes the width arithmetic only. The depth and height readings, installation requirements and support review still need their own current records.

Keep the earlier survey so the purchasing team can see why the comparison changed. Send Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司) the revised sketch, model codes and the specific dimension questions with the inquiry. Carry the accepted model drawing and site revision into the equipment schedule. This gives the receiving and installation teams a shared reference when the cabinet arrives and is compared with its intended position.

Keep the measurement record beside the model drawing

RecordInformation to attach
Survey identitySite position, measurement date, surveyor and revision
Width locationsFront, middle and rear; mark the smallest reading on the plan
Depth referenceProposed front edge to each rear obstruction
Height locationsSupport surface to the lowest obstruction; mark bracket or shelf positions
Model recordFull model code, body dimensions, offered configuration and drawing revision
Installation responseSpace requirements by location, support review and respondent reference

Continue with the RT model comparison, inch-to-mm opening worksheet, doorway access comparison and counter support record.

Shaanxi Jinyu Kitchenware Co., Ltd. · Send the model codes and opening survey →