Checkout location · Staff-side service · Six model sizes
What Size Display Cooler Fits Behind a Checkout Counter?
Compare the cabinet body, supporting surface and staff working area together. Use six recorded JINYU sizes and worked bay calculations to prepare a measured shortlist.
Compare the six cabinets →
Six cabinet outlines for a checkout shortlist
| JINYU model | W × D × H (mm) | Capacity | Shelves |
|---|---|---|---|
| GN-660RT | 660 × 530 × 730 | 102 L | 2 |
| GN-900CT | 900 × 530 × 730 | 120 L | 2 chrome-plated shelves |
| GN-1000R2-J | 1000 × 660 × 1200 | 160 L | 2 adjustable shelves |
| GN-900L | 900 × 740 × 1400 | 235 L | 2 shelves plus base deck |
| GN-620FS | 620 × 700 × 2018 | 410 L | 4 wire shelves |
| GN-1000XD | 1000 × 850 × 1175 | 535 L | 2 adjustable shelves |
Which dimensions decide whether a cooler fits behind the checkout?
Measure the available width, depth and height as three separate limits. Then identify the supporting surface: a cabinet placed on a counter starts above floor level, while a floor-standing model starts at the floor. A staff-side checkout position also needs a measured route between the till, the display opening and the packing surface. Mark those tasks on the same plan before comparing cabinet outlines.
The six JINYU models below span 620-1000 mm in width, 530-850 mm in depth and 730-2018 mm in cabinet height. The smallest frontage is therefore not the lowest cabinet. Use the dimensional table to eliminate body-size conflicts, then request the installation drawing for the remaining candidates.
How does a 1150 mm-wide, 700 mm-deep bay narrow the shortlist?
Consider an illustrative buyer bay measuring 1150 mm wide and 700 mm deep, with 1550 mm available vertically above its supporting surface. GN-1000R2-J measures 1000 × 660 × 1200 mm. Subtracting its body dimensions leaves 150 mm across the width, 40 mm in depth and 350 mm vertically. Those are total arithmetic remainders, with no installation or access allowance assigned.
GN-900L is 740 mm deep, so its body exceeds that bay depth by 40 mm. GN-1000XD is 850 mm deep and exceeds it by 150 mm. GN-620FS meets the example width and depth limits but its 2018 mm height exceeds the stated vertical space by 468 mm. Neither a narrow frontage nor a large capacity resolves those conflicts.
Should the display sit on the checkout counter or on the floor?
GN-660RT and GN-900CT are countertop candidates, each 530 mm deep and 730 mm high. On an illustrative 900 mm-high supporting counter, their upper cabinet edge is 1630 mm above the floor: 900 + 730. GN-1000R2-J is a floor-standing candidate with a 1200 mm body height. Show both elevations on the drawing rather than comparing 730 mm directly with 1200 mm.
The RT and CT cabinets also require a support review for the selected arrangement. Send the counter construction, available support area and requested equipment weight information with the inquiry. A depth comparison establishes a cabinet outline; the support assessment needs the actual contact arrangement and loading information.
How much staff aisle remains behind the till?
Use a measured cross-section from the checkout back edge to the opposing fixed surface. In an illustrative 1800 mm-wide staff zone, placing the 660 mm-deep GN-1000R2-J against the opposite side leaves 1140 mm between the cabinet body and checkout. A 740 mm-deep GN-900L leaves 1060 mm; an 850 mm-deep GN-1000XD leaves 950 mm. These values describe the example before any projections, installation spacing or people are added.
Draw the till operator, packing position and intended replenishment container into that remaining area. Add door or drawer movement from the offered model drawing. Have the site team review the resulting circulation against local requirements; the body subtraction supplies no minimum aisle standard.
Does an open-front cooler suit a staff-side location?
GN-900L lists an open front, two shelves plus a base deck and a 235 L capacity. In a location behind the checkout, identify who actually takes products from that open front. If staff serve every item, show their approach and the replenishment stock position. If customers select directly, their route must reach the display without relying on the staff work zone as an unmarked passage.
Compare that arrangement with the enclosed cake-display candidates using the same plan. Request the access-side drawing for each shortlisted model. Record customer selection, staff loading and cleaning access separately so the proposed position addresses all three tasks.
Can the listed litres tell me how many packs will fit?
Use litres to identify the catalogue record, then measure the finished products. GN-660RT lists 102 L, GN-900CT 120 L and GN-1000R2-J 160 L. Their outside dimensions and shelf arrangements differ. A carton, cake board or bottle needs a usable shelf width, depth and clear height at the nominated setting before a quantity can be assigned.
For each product reference, send the complete outside measurements including projecting lids or packaging. Ask for a layout showing the support level, orientation and loading opening. Keep the display quantity separate from reserve stock beside the checkout. This prevents a capacity comparison from becoming an unsupported pack-count assumption.
What should the checkout site drawing include?
Give the plan a revision and label the checkout front, staff side, display front and replenishment route. Record the three bay limits with their measurement endpoints. Add the counter height to the elevation, plus wall shelves, payment equipment, cables and fixed projections that share the proposed space. Photograph the location from both ends of the staff aisle and cross-reference each image on the plan.
Ask for a model-specific installation and access drawing against those labels. Include the receiving route in a separate view with the requested packed dimensions. A cabinet body that fits the trading position still needs an assessed route into that position.
What should I send with a behind-checkout cooler inquiry?
Send Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司) the selected model codes, measured bay, counter elevation and numbered site photographs. Attach the product list and describe whether staff serve products or customers select them. State the site electrical supply separately and request the offered configuration documents.
Use the worksheet below to keep each question tied to an evidence item. Retain the returned drawing revision with the model comparison, then update the plan if the cabinet or checkout position changes. The final discussion can then address specific measurements and access tasks rather than a general request for a cooler that fits.
Behind-checkout site and model response worksheet
| Review | Buyer supplies | Requested response |
|---|---|---|
| Body envelope | Bay width, depth and vertical limit; floor or counter reference | Outside dimensions and installation drawing for the selected model |
| Counter elevation | Supporting surface height and construction | Equipment loading and support information for the arrangement |
| Staff movement | Till, packing position and measured cross-section | Access drawing with opening positions and service areas |
| Product loading | Finished-pack dimensions, shelf assignment and orientation | Usable shelf and opening measurements for those packs |
| Receiving route | Numbered doors, turns and unloading endpoint | Packed dimensions and handling information for the offered unit |