Measured site elevation · three JINYU models

Display Fridge Size Under a Sloping Overhead Boundary

Compare three 1000 mm JINYU display fridge bodies under a measured slope. Calculate corner heights, cabinet offsets and vertical differences before preparing a site drawing.

Calculate the body-to-boundary difference · Read six buyer questions

JINYU GN-1000R2-J economy straight glass cake display in a cafe or bakery
GN-1000R2-J: 1000 × 660 × 1200 mm. The overhead geometry below is an illustrative site example.

Three equal frontages, different heights and depths

Recorded body sizes in mm; capacity and rated power stay attached to each model.
ModelW × D × HCapacityShelvesSupplyPower
GN-1000R2-J1000 × 660 × 1200160 L2 adjustable shelves220-240V/50Hz455 W
GN-1000R3-J1000 × 660 × 1300228 L3 adjustable shelves220-240V/50Hz460 W
GN-1000XD1000 × 850 × 1175535 L2 adjustable shelves110V/60Hz480 W

Check both cabinet edges against a straight overhead line

All dimensions are in mm from the same floor datum. Defaults describe an illustrative site. The results compare stationary body outlines; installation spacing and access dimensions belong on the selected configuration's drawing.

Worked front elevation beneath a descending boundaryOverhead height falls from 1600 to 1000 mm across a 2000 mm run. A 1000 mm wide cabinet starts at offset 200 mm. Heights at its left and right edges are 1540 and 1240 mm.1600 mm1000 mm200 mm offset1000 mm body widthCabinet front elevation1240 mm at right edge

The diagram labels the default example; use the table for edited values.

Worked example: corner heights 1540 and 1240 mm; lower boundary 1240 mm.

Difference = lower overhead height - body height. Negative values indicate a body crossing the boundary; zero means the outlines meet.
ModelLeft overheadRight overheadLower overheadBody heightDifference (mm)
GN-1000R2-J154012401240120040
GN-1000R3-J1540124012401300-60
GN-1000XD154012401240117565

How do I check display fridge size beneath a sloping shelf or soffit?

Measure the underside height at two ends of the proposed run, using the same floor datum, and record the horizontal distance between them. Draw the cabinet front elevation within that run. A slope means that the available height changes with position: measuring only above the cabinet centre can hide a conflict at its taller-side corner. Keep the horizontal cabinet width and the vertical body height as separate dimensions.

For a straight overhead edge, height at position x is H-left + (H-right - H-left) × x ÷ run length. Calculate that height at both cabinet edges and use the smaller result for the vertical comparison. This page applies that geometry to three recorded JINYU bodies. The calculation describes a straight boundary in one elevation. A curved underside, a local bracket or a shelf that changes depth needs additional measured points on the drawing.

Which three display fridge sizes can I compare here?

GN-1000R2-J measures 1000 × 660 × 1200 mm, with 160 L recorded capacity and 455 W rated power. GN-1000R3-J measures 1000 × 660 × 1300 mm, with 228 L and 460 W. GN-1000XD measures 1000 × 850 × 1175 mm, with 535 L and 480 W. Dimensions follow width × depth × height. Each body is 1000 mm wide, so their vertical differences can be compared at the same horizontal position.

R2-J has two adjustable shelves; R3-J has three adjustable shelves. XD records two shelves and two drawers. Its body is 190 mm deeper than either economy cabinet. The electrical records also differ: R2-J and R3-J list 220-240V/50Hz, while XD lists 110V/60Hz. Keep those configurations attached to the model code when shortlisting; an equal frontage alone does not describe the required floor area, shelf arrangement or electrical connection.

What does the worked 2000 mm sloping run show?

The illustrative overhead boundary is 1600 mm above the floor at its left end and 1000 mm at its right end, across a 2000 mm run. Put the left cabinet edge 200 mm from the run origin. The two cabinet edges are then at x = 200 and x = 1200 mm. Overhead heights at those edges are 1540 and 1240 mm. The smaller height, 1240 mm, controls the rectangular body comparison.

Subtract each body height from 1240 mm. GN-1000R2-J leaves a 40 mm geometric difference; GN-1000R3-J exceeds the boundary by 60 mm; GN-1000XD leaves 65 mm. These figures are a worked site example, not installation spacing. A positive difference only places the recorded body below the drawn edge. Apply the offered configuration's installation drawing, ventilation requirements and service access separately before selecting a final position.

Can moving the same cabinet sideways change the result?

Yes. In this descending example, moving the left cabinet edge from x = 200 mm to x = 0 moves its right edge to x = 1000 mm. The smaller overhead height becomes 1300 mm instead of 1240 mm. The geometric differences become 100 mm for R2-J, zero for R3-J and 125 mm for XD. A 200 mm horizontal movement has therefore changed the vertical comparison by 60 mm.

Zero means the two drawn edges meet. It supplies no space for installation or movement. Mark the new position relative to walls, tills and the staff approach, then check whether that position remains useful for serving and replenishment. The calculator accepts either an ascending or descending straight edge and evaluates both cabinet ends. Keep the full body inside the measured run; extrapolating beyond the surveyed endpoints would use heights that were never measured.

What else belongs on the plan besides the overhead height?

Draw the floor plan beside the elevation. R2-J and R3-J occupy 1000 × 660 mm body rectangles, while XD occupies 1000 × 850 mm. Show where the overhead object sits in depth: a front fascia and a rear wall shelf can cross different parts of the appliance. A single front elevation cannot describe every three-dimensional obstruction, particularly brackets, cables or irregular ceiling shapes.

Label the service side, the rear staff route and the stock or tray removal movement. The three model records describe sliding service doors; XD also has drawers. Request the usable openings and drawer travel for that offered cabinet. Add the delivery route using the shipment's packed dimensions and handling arrangement. A body that lies below the overhead line in its final position still needs a practical route into that position and room for the work performed around it.

What should I send with a sloping-space display fridge inquiry?

Send a labelled elevation with the two measured underside heights, run length, cabinet offset and floor datum. Add the full model code, a floor plan showing body depth and the overhead object's projection, and photographs labelled with the same left and right endpoints. Include local obstructions as separate dimensions. Keep the calculator values on the drawing so the arithmetic can be checked against the site readings.

Ask JINYU, Shaanxi Jinyu Kitchenware Co., Ltd. (陕西金宇厨具有限公司), for the selected configuration's installation drawing and the shelf, door and drawer measurements needed for your assortment. Include the actual site supply alongside the model's recorded voltage and frequency. Retain the returned drawing with the same site-plan revision. When either an endpoint height or cabinet position changes, recalculate the corner heights and update the elevation before using the comparison in the purchase brief.